welcome,guest
TitleProduct

U bend Tube Bundle|U bend Boiler Tubes

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2024-08-08 17:34

  • Browse the number:

    0

Send an inquiries

Company Profile

Shanghai T.S. Industrial Co.,Ltd

By certification [File Integrity]

Contact: kebyge(Mr.)  

Email:

Telephone:

Phone:

Area: Beijing

address: Room 408, No.2, Lane 1588 Youyi Road, Baoshan, Shanghai, China

Website: http://b0fc49ec.masxlyjjx.com/

Product details
"U" bent tubes for heat exchangers can be supplied in accordance ASME SA556, ASME SA179, ASME SA192, ASME SA213, ASME SA688, ASME SA803

Reference standards and Steel Grades: 304/304L Austenitic, 316/316L Austenitic, 2205 Duplex, 2507 Duplex,439 Ferritic

ASTM A556 Gr. A2 - B2 - C2, ASME SA556 Sect.II Gr. A2 - B2 - C2

"U" Bent tubes in accordance with the standards detailed in table 1, part A can be requested.

The bent area can be subject to stress relieving heat treatment by joule effect in inert atmosphere.

- Minimum radius treated = 28 mm.

- Maximum radius treated = 750 mm.

2. U bend Tube Bundle Dimensions and lengths

Tubes with the following external diameters in mm can be bent a upon agreement: 15,8 - 16,0 - 17,0 - 18,0 - 19,05 - 20,0 - 21,3 - 25,4 - 26,7 - 31,8 -38,1.

The minimum feasible radius is : 1,5 x external diameter

The maximum feasible radius is 1500 mm.

A556 U bend Tube

3. U bend Tube Bundle Tolerances

Tolerances (diameter and wall thickness) according to ASTM A 556 or given in the standards detailed in table 1 point A are respected.

Bending tolerances. The tolerances stipulated in ASTM A 556 are respected.

Minimum wall thickness tolerances in the bent area conforming to the TEMA standard "Class R heat exchangers" can be requested or in accordance with specific requests.

4. U bend Tube Bundle Checks and test

All the mechanical and technological tests stipulated in the cited standards are carried out.

Leak tightness test: electromagnetic test (Eddy Current) is performed on straight tubes. Hydrostatic test on bent tubes is performed only if expressly requested, specifying the test pressure

5. U bend Tube Bundle Standard Technical Range

OD 9.5mm - 38.1mm

WT up to 6.35mm

Bending radii 1.25 x OD up to 1700mm

Bends can be supplied in accordance with TEMA R / ASTM SA/A556

Leg length up to 15000mm

6. U bend Tube Bundle Test

Heat treatment where required by electric furnance or direct resistance

Hydrotesting up to 10,000 psi
link:https://www.lordfintube.com/