welcome,guest
Home » Products »
TitleProduct

Siemens Nxairs-12kV Air/gas Insulated Medium Voltage Electrical/power Distribution Panels/switchgear

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shaanxi

  • Validity to:

    Long-term effective

  • Last update:

    2017-08-14 14:25

  • Browse the number:

    53

Send an inquiries

Company Profile

Shaanxi XD HI-TECH Medium-Low Voltage Apparatus Co.,Ltd

By certification [File Integrity]

Contact: xidiangaoke(Mr.)  

Email:

Telephone:

Phone:

Area: Shaanxi

address: NO.6. 2nd road, Heping Industrial Park, Xi Xian New District, Xi’an City

Website: http://www.xdhi-tswitchgears.com/ http://xidiangaoke.masxlyjjx.com/

Product details


SIEMENS NXAirS-12 kV Air Insulation Withdrawable Metal-clad medium-voltage Switchgear


1. Characteristics

·  Mechanical dynamic position indicator

·  The closing/opening status of disconnecting switch and grounding switch can be indicated respectively on mechanical dynamic position indicator.

·  Operating handle socket and control elements are obviously set adjacent to closing/opening indicator of controlled switches.

·  All the switch operations can be carried out when high-voltage compartment door closed.

·  All the parts and components installation heights meet the requirements of human engineering.

·  Options: Capacitive electric indicator can be used to detect feeder or power of busbar.


2. Electric Parameters

- Rated voltage

kV

7.2

12

- Rated frequency

Hz

50

50

-   Rated short-time power frequency withstand voltage (interphase, to-ground)

kV

32

42

- Rated lightning impulse withstand voltage   (interphase, to-ground)

kV

60

75

-   Rated short-circuit breaking current

MAX

kA

40*

40*

- Rated short-time withstand current, 4s

MAX

kA

40*

40*

- Rated short-circuit closing current

MAX

kA

100*

100*

- Rated peak withstand current

MAX

kA

100*

100*

- Rated bus current

MAX

A

4000

4000

- Feeder current1)

A



Circuit breaker cabinet

4000

4000

Contactor cabinet

250

160

Disconnecting handcart cabinet

4000

4000

Bus segment cabinet

4000

4000

Bus lifting cabinet

4000

4000

·  *: It is applicable to switchgears outside of contactor cabinet.


3. Overall Dimensions

 

Width

mm

Circuit breaker cabinet


≤630A

650

1250A~2500A

800

3150A~4000A

1000

Disconnecting handcart cabinet


≤2500A

800

3150A~4000A

1000

Transformer used in substation

1000